TECHNICAL
INFORMATION
NET FREE AREA CHARTS:
1:150
Ratio-no Moisture Barrier
1:300 Ratio-w/ Moisture Barrier
1:150
ratio: Net Free Area
Table-Use when no Moisture Barrier is installed.
The MINIMUM
attic ventilation required by the Building Codes is 1 square
foot of total net free area per 150 square feet of attic when
no moisture barrier is used.
A
Balanced System
requires soffit ventilation in an amount equal to or greater
than the amount of ridge ventilation.
See soffit vent manufacturer's information on the Net
Free Area provided by soffit vent product.
Attic
Area
(SF) |
Minimum
NFA
(SF) |
Exhaust
NFA (SF) |
Length
of
Roof Saver
(FT) |
Intake
NFA (SF) |
1000 |
6.67 |
3.33 |
31.6 |
3.33 |
1100 |
7.33 |
3.67 |
34.7 |
3.67 |
1200 |
8.00 |
4.00 |
37.9 |
4.00 |
1300 |
8.67 |
4.33 |
41.1 |
4.33 |
1400 |
9.33 |
4.67 |
44.2 |
4.67 |
1500 |
10.00 |
5.00 |
47.4 |
5.00 |
1600 |
10.67 |
5.33 |
50.5 |
5.33 |
1700 |
11.33 |
5.67 |
53.7 |
5.67 |
1800 |
12.00 |
6.00 |
56.8 |
6.00 |
1900 |
12.67 |
6.33 |
60.0 |
6.33 |
2000 |
13.33 |
6.67 |
63.2 |
6.67 |
2100 |
14.00 |
7.00 |
66.3 |
7.00 |
2200 |
14.67 |
7.33 |
69.5 |
7.33 |
2300 |
15.33 |
7.67 |
72.6 |
7.67 |
2400 |
16.00 |
8.00 |
75.8 |
8.00 |
2500 |
16.67 |
8.33 |
39.5 |
8.33 |
2600 |
17.33 |
8.67 |
41.1 |
8.67 |
2700 |
18.00 |
9.00 |
42.6 |
9.00 |
2800 |
18.67 |
9.33 |
44.2 |
9.33 |
2900 |
19.33 |
9.67 |
45.8 |
9.67 |
3000 |
20.00 |
10.00 |
47.4 |
10.00 |
See soffit vent manufacturers instructions for NFA calculation. |
1:300
ratio: Net Free Area
Table-Use when Moisture Barrier is installed
The MINIMUM attic ventilation required
by the Building Codes is 1 square foot of total net free area
per 300 square feet of attic when a moisture barrier is installed.
A
Balanced System requires soffit ventilation in an amount equal
to or greater than the amount of ridge ventilation. See soffit
vent manufacturer's information on the Net Free Area provided
by soffit vent product.
Attic
Area
(SF) |
Total NFA
(SF) |
Ridge Ventilation
NFA (SF) |
Length
of
Roof Saver
(FT)
|
Sofit Ventilation
NFA (SF) |
1000 |
3.33 |
1.67 |
15.8 |
1.67 |
1100 |
3.67 |
1.83 |
17.4 |
1.83 |
1200 |
4.00 |
2.00 |
18.9 |
2.00 |
1300 |
4.33 |
2.17 |
20.5 |
2.17 |
1400 |
4.67 |
2.33 |
22.1 |
2.33 |
1500 |
5.00 |
2.50 |
23.7 |
2.50 |
1600 |
5.33 |
2.67 |
25.3 |
2.67 |
1700 |
5.67 |
2.83 |
26.8 |
2.83 |
1800 |
6.00 |
3.00 |
28.4 |
3.00 |
1900 |
6.33 |
3.17 |
30.0 |
3.17 |
2000 |
6.67 |
3.33 |
31.6 |
3.33 |
2100 |
7.00 |
3.50 |
33.2 |
3.50 |
2200 |
7.33 |
3.67 |
34.7 |
3.67 |
2300 |
7.67 |
3.83 |
36.3 |
3.83 |
2400 |
8.00 |
4.00 |
37.9 |
4.00 |
2500 |
8.33 |
4.17 |
39.5 |
4.17 |
2600 |
8.67 |
4.33 |
41.1 |
4.33 |
2700 |
9.00 |
4.50 |
42.6 |
4.50 |
2800 |
9.33 |
4.67 |
44.2 |
4.67 |
2900 |
9.67 |
4.83 |
45.8 |
4.83 |
3000 |
10.00 |
5.00 |
47.4 |
5.00 |
See soffit vent manufacturers instructions for NFA calculation. |
|