What
materials are required to install Roof Saver rolled ridge
vent?
- Roof
Saver rolled ridge vent
- Roofing
nails (included in package)
- Wind
deflectors where required
What
tools are needed to install Roof Saver rolled ridge vent?
- Safety
glasses
- Power
saw
- Utility
knife or scissors
- Tape
measure
- Nail
gun or hammer
Wind
deflectors are required in areas where snow and/or rain are
accompanied by winds exceeding 80 mph to prevent the infiltration
of snow and/or rain into the attic. Wind deflectors must be
used where required by building codes.
How
is the required amount of ridge/soffit ventilation determined?
Proper
operation of attic ventilation systems requires a combination
of exhaust through the ridge vent and intake through soffit
vents. The most efficient operation is realized through a
balanced system with equal amounts of ventilation along the
ridge and soffit areas. When a balanced system cannot be constructed,
soffit vents must provide more than 50% of the total required
ventilation with the remaining ventilation provided through
the ridge vent.
The ratio of Net Free Ventilation Area to horizontal Attic
Area is used to calculate the minimum amount of total ventilation.
The 1/150 ratio applies when uniform distribution of soffit
and ridge vents cannot be achieved or when no vapor retarder
is present. The 1/300 ratio applies when proper distribution
of soffit and ridge vents is achievable or if a vapor retarder
is present.
|